Browse technical resources about solar mounting systems, tracker technology, structural design, and installation best practices.
HOME / Battery Lab Machine, Supercapacitor Equipment, Battery - BeTheFuture Solar Foundation & Infrastructure
Telecom base station battery is a kind of energy storage equipment dedicatedly designed to provide backup power for telecom base stations, applied to supply continuous and stable power to base station equipment when the utility power is interrupted or malfunctions, which plays a vital role in the stable operation of telecom base stations.
Before 1960, the dismantling of batteries was mainly with the help of axes, because organics were not allowed to enter the furnace during the processing process, and the battery could not be directly added to the furnace. While this situation has now improved in many countries, especially in developed countries, it. To minimize human contact with the battery dismantling process, the spent batteries should be transported to the open apparatus by automatic conveyor belts or small vehicles as much as possible. Once the battery. Various contaminations may exist in lead recycling. Several common situations that affect the environment during the battery disassembly and.
Lead acid batteries can sometimes sustain damage that cannot be repaired through reconditioning. A common issue is sulfation, where lead sulfate crystals accumulate on the battery plates. Severe sulfation may reduce the battery's capacity beyond recovery, making replacement necessary.
A lead acid battery, including flooded electrolyte types, should not have its acid completely removed once it has been filled and charged. It is important not to remove the acid. A lead acid battery consists of several major components, including the positive electrode, negative electrode, sulphuric acid, separators, and tubular bags.
If a lead acid battery runs out of water, meaning the electrolyte has fully dried up or the battery has been tilted or stored upside down causing the electrolyte to spill, this is the main concern.
Steps to Recondition a Lead-Acid Battery Safety First: Wear safety goggles and gloves to protect yourself from the corrosive acid. Remove the Battery: Take the battery out of the vehicle or equipment. Open the Cells: Remove the caps from the battery cells. Some batteries have screw-in caps, while others have rubber plugs.
A lead acid battery is a type of rechargeable battery that has positive and negative plates fully immersed in electrolyte, which is dilute sulphuric acid.
When a lead acid battery is drained of its acid, the wet moist negative electrodes come in contact with atmospheric oxygen, triggering an exothermic reaction that releases heat and discharges the negative plates (electrodes), oxidizing the sponge lead to lead oxide.
Below is a detailed explanation of the primary technical parameters of lithium batteries, along with additional related knowledge, to assist you in better applying and managing energy storage systems.
Learn about the key technical parameters of lithium batteries, including capacity, voltage, discharge rate, and safety, to optimize performance and enhance the reliability of energy storage systems. Lithium batteries play a crucial role in energy storage systems, providing stable and reliable energy for the entire system.
Lithium batteries play a crucial role in energy storage systems, providing stable and reliable energy for the entire system. Understanding the key technical parameters of lithium batteries not only helps us grasp their performance characteristics but also enhances the overall efficiency of energy storage systems.
Specific capacity, energy density, power density, efficiency, and charge/discharge times are determined, with specific C-rates correlating to the inspection time. The test scheme must specify the working voltage window, C-rate, weight, and thickness of electrodes to accurately determine the lifespan of the LIBs. 3.4.2.
Energy density is often a more relevant indicator than capacity in practical applications. Current lithium-ion battery technology achieves energy densities of approximately 100 to 200 Wh/kg. This level is relatively low and poses challenges in various applications, particularly in electric vehicles where both weight and volume are restricted.
LIBs are prominent energy storage devices to meet the growing energy demands of the modern era. They offer high specific capacity, energy density, thermal stability, and long calendar life compared to other types of batteries. LIBs are used in a diverse range of applications, from powering household appliances to supporting electric vehicles.
Battery storage is a technology that enables power system operators and utilities to store energy for later use.
For the purposes of this document, the following terms and definitions apply; Power Generating Modules are categorised in EREC G99 as Power Park Modules (PPM) or Synchronous Power Generating Modules (SPGM). Both contain one or more. When you are ready to submit a formal application for connection, we will require information from you to enable us to make a reasonable assessment of the works required to facilitate the. Discussing your plans with us at an early stage can help to provide a better insight to any potential network reinforcement and complexity issues that. If you are not ready to enter into a formal agreement for connection works, or you do not yet have full details of the specific conditions required, you.
Solar lights have rechargeable batteries that last about four years without replacements, while the lights and LED fixtures can last approximately ten years.
On the other hand, NiCad batteries may reduce the lifespan of solar lights to just 1 year because of memory problems. The longevity of solar lights can range from 6 months to 2 years based on the type of battery used. Understanding the impact of battery technology on solar lights is important for ensuring their durability.
Solar batteries store energy generated from solar panels. These components play a key role in your solar system, especially when it comes to energy availability during power outages or low sunlight conditions. Lead-acid batteries are the most common type used in solar systems. They can last around 3 to 5 years, depending on usage and maintenance.
To improve solar light longevity, consider placing the lights in areas with direct sunlight for at least 6-8 hours each day. Keep the solar panels clean and free from any debris to ensure maximum sunlight absorption. Additionally, switching off the lights when not in use can help extend battery life.
Keep the solar panels clean and free from any debris to ensure maximum sunlight absorption. Additionally, switching off the lights when not in use can help extend battery life. When it comes to making the most of your solar lights, keeping an eye on the battery life is crucial. Regular monitoring guarantees they stay lit up when needed.
If you're considering whether or not to get a solar battery, one of the deciding factors will be how long they last. After all, with solar panels typically lasting 25-30 years, you'll want to know how many battery systems you'll have to buy to match your panels' lifespan.
Lithium-ion batteries stand out for their longevity and performance. Typically, they last between 10 to 15 years. Their design allows for a higher depth of discharge (DoD), meaning you can use more of the stored energy without harming battery life.
Sealed lead acid batteries may be charged by using any of the following charging techniques: 1. Constant Voltage 2. Constant Current 3. Taper Current 4. Two Step Constant Voltage To obtain maximum battery ser. During constant voltage or taper charging, the battery's current acceptance decreases as voltage and state of charge increase. The battery is fully charged once the current stabilize. Selecting the appropriate charging method for your sealed lead acid battery depends on the intended u. Constant voltage charging is the best method to charge sealed lead acid batteries. Depending on the application, batteries may be charged either on a continuous or no. Constant current charging is suited for applications where discharged ampere-hours of the preceding discharge cycle are known. Charge time and charge quantity can easily be cal.
The lead-acid battery mainly uses two types of charging methods namely the constant voltage charging and constant current charging. It is the most common method of charging the lead acid battery. It reduces the charging time and increases the capacity up to 20%. But this method reduces the efficiency by approximately 10%.
Just multiply the voltages by 2 for 24V or 4 for 48V batteries. The only way to get an accurate reading of a lead acid battery's state of charge from voltage is to measure its open circuit voltage. This means the battery must be disconnected from all loads and chargers and allowed to rest for several hours until its voltage stabilizes.
The optimal charging voltage for 48V flooded lead acid batteries is typically around 58V to 62V at the start of charging. Sealed batteries may need slightly higher voltages. Refer to the battery specifications. How Can I Revive a Dead Lead Acid Battery?
Customers often ask us about the ideal charging current for recharging our AGM sealed lead acid batteries. We have the answer: 25% of the battery capacity. The battery capacity is indicated by Ah (Ampere Hour). For example: In a 12V 45Ah Sealed Lead Acid Battery, the capacity is 45 Ah.
For example: In a 12V 45Ah Sealed Lead Acid Battery, the capacity is 45 Ah. So, the charging current should be no more than 11.25 Amps (to prevent thermal runaway and battery expiration). Importantly, if you have other equipment connected to the battery during chargning, it also needs to be powered, so you need to add that to your calculations.
In this method the charging current is high in the beginning when a battery is in discharged condition, and it gradually drops off as the battery picks up charge resulting in increased back emf. Charging at constant voltage may be carried out only when the batteries have the same voltage, for example, 6 or 12 or 24 V.
Learn how raw materials like lead, sulfuric acid, and water come together to form these essential energy storage devices. From grid casting to battery formation, we explain each step in detail.
This document provides an overview of the lead acid battery manufacturing process. It discusses the key steps which include alloy production, grid casting, paste mixing and pasting, plate curing, and assembly. The alloy production process involves preparing mother alloy and KL-alloy from reclaimed lead using furnaces.
The lead battery is manufactured by using lead alloy ingots and lead oxide It comprises two chemically dissimilar leads based plates immersed in sulphuric acid solution. The positive plate is made up of lead dioxide PbO2 and the negative plate with pure lead.
A typical lead–acid battery contains a mixture with varying concentrations of water and acid. Sulfuric acid has a higher density than water, which causes the acid formed at the plates during charging to flow downward and collect at the bottom of the battery.
During the charging process, the cycle is reversed, that is, lead sulphate and water are converted to lead, lead oxide and electrolyte of sulphuric acid by an external charging source. This process is reversible, which means lead acid battery can be discharged or recharged many times.
The positive plate is made up of lead dioxide PbO2 and the negative plate with pure lead. The nominal electric potential between these two plates is 2 volts when these plates are immersed in dilute sulfuric acid. This potential is universal for all lead acid batteries.
In applications, a nominal 12V lead-acid battery is frequently created by connecting six single-cell lead-acid batteries in series. Additionally, it can be incorporated into 24V, 36V, and 48V batteries. Further, the lead acid manufacturing process has been discussed in detail. Lead Acid Battery Manufacturing Equipment Process 1.
The full battery designation identifies not only the size, shape and terminal layout of the battery but also the chemistry (and therefore the voltage per cell) and the number of cells in the battery. For example, a CR123 battery is always LiMnO 2 ('Lithium') chemistry, in addition to its unique size. This is a list of the sizes, shapes, and general characteristics of some common primary and secondary in household, automotive and light industrial use. The complete no. Coin-shaped cells are thin compared to their diameter. is usually stamped on the metal casing. The IEC prefix "CR" denotes lithium manganese dioxide chemistry. Since LiMnO2 cells pro.
Batteries can be classified according to their chemistry or specific electrochemical composition, which heavily dictates the reactions that will occur within the cells to convert chemical to electrical energy. Battery chemistry tells the electrode and electrolyte materials to be used for the battery construction.
Although BCI is the most common battery group classification system in the United States, others do exist. EN and DIN are other battery group classification systems that you will sometimes see in owner's manuals or when shopping for batteries.
In this study, two types of classification settings are considered. The first setting considers y i = {0 1}, which is a binary classification task grouping batteries into {s h o r t, l o n g} lifetime.
The complete nomenclature for a battery specifies size, chemistry, terminal arrangement, and special characteristics. The same physically interchangeable cell size or battery size may have widely different characteristics; physical interchangeability is not the sole factor in substituting a battery. [ 1 ]
Considering the above, it appears timely to propose a simple and uniform classification system encompassing all battery types. Conceptually, every battery is simply made of three layers: positive electrode layer, electrolyte layer, negative electrode layer.
Primary batteries come in three major chemistries: (1) zinc–carbon and (2) alkaline zinc–manganese, and (3) lithium (or lithium-metal) battery. Zinc–carbon batteries is among the earliest commercially available primary cells. It is composed of a solid, high-purity zinc anode (99.99%).
The zinc–bromine (ZBRFB) is a hybrid flow battery. A solution of is stored in two tanks. When the battery is charged or discharged, the solutions (electrolytes) are pumped through a reactor stack from one tank to the other. One tank is used to store the electrolyte for positive electrode reactions, and the other stores the negative. range between 60 and 85 W·h/kg.
Zinc bromine flow batteries or Zinc bromine redux flow batteries (ZBFBs or ZBFRBs) are a type of rechargeable electrochemical energy storage system that relies on the redox reactions between zinc and bromine. Like all flow batteries, ZFBs are unique in that the electrolytes are not solid-state that store energy in metals.
Three examples of zinc–bromine flow batteries are ZBB Energy Corporation′s Zinc Energy Storage System (ZESS), RedFlow Limited′s Zinc Bromine Module (ZBM), and Premium Power′s Zinc-Flow Technology.
Zinc-bromine flow batteries (ZBFBs) offer great potential for large-scale energy storage owing to the inherent high energy density and low cost. However, practical applications of this technology are hindered by low power density and short cycle life, mainly due to large polarization and non-uniform zinc deposition.
While zinc bromine flow batteries offer a plethora of benefits, they do come with certain challenges. These include lower energy density compared to lithium-ion batteries, lower round-trip efficiency, and the need for periodic full discharges to prevent the formation of zinc dendrites, which could puncture the separator.
The leading potential application is stationary energy storage, either for the grid, or for domestic or stand-alone power systems. The aqueous electrolyte makes the system less prone to overheating and fire compared with lithium-ion battery systems. Zinc–bromine batteries can be split into two groups: flow batteries and non-flow batteries.
In the early stage of zinc–bromine batteries, electrodes were immersed in a non-flowing solution of zinc–bromide that was developed as a flowing electrolyte over time. Both the zinc–bromine static (non-flow) system and the flow system share the same electrochemistry, albeit with different features and limitations.
Each lithium battery has a positive (+) and a negative (-) terminal. Correctly identifying these terminals is key for safe and effective use. Interchanging them can result in serious device damage.
Maybe you have noticed that, for example, car lithium batteries always have cylinder shaped terminals, motorcycle batteries have square shaped terminals, some other terminals are simple tabs sticking straight out of the top of lithium batteries. How to Reduce Poor Connection Chances? What's the Difference between Terminals and Lugs?
Most consumer devices that have lithium single-cell batteries have 4 connections. I've noticed the following diverse types of devices, this is true: The 4-connection rule seems to hold even with devices that have multi-cell batteries like cordless drills.
Lead terminals are hence a stable, reliable choice for lithium batteries. The Significance of Terminal Material in Lithium Batteries! Lithium battery terminals are vital for battery efficiency.
When it comes to lithium batteries, there exists a diverse array of terminal configurations to suit different applications and devices. Two common types include button top and flat top terminals. Button top terminals feature a raised positive terminal that resembles a small button on top of the battery cell.
In lithium ion battery systems, there exist two such connectors – the battery terminals positive and negative. On one side, the positive terminal connects to the cathode of the battery. Then, the negative terminal connects to the battery's anode. A safe and secure connection is vital for a battery's efficient operation.
The electrical energy in batteries travels through their terminals the, cathode and the anode, or what we like to call positive and negative terminals. Lithium batteries come in many shapes and sizes, so do lithium battery terminals. The application range of lithium battery is quite wide from bracelet to car.
The end result may include (a) physical expansion of plates, (b) increased internal resistance, (c) reduced power capability, and (d) eventual battery failure.
If the water level gets too low, the plates will start to corrode and the battery will eventually fail. If you have a lead-acid battery, it is important to keep it full of water. If the water level gets too low, the battery are ruined. What Happens If Lead Acid Battery Runs Out of Water?
When a lead acid battery is drained of its acid, the wet moist negative electrodes come in contact with atmospheric oxygen, triggering an exothermic reaction that releases heat and discharges the negative plates (electrodes), oxidizing the sponge lead to lead oxide.
A lead acid battery is a type of rechargeable battery that has positive and negative plates fully immersed in electrolyte, which is dilute sulphuric acid.
A lead acid battery, including flooded electrolyte types, should not have its acid completely removed once it has been filled and charged. It is important not to remove the acid. A lead acid battery consists of several major components, including the positive electrode, negative electrode, sulphuric acid, separators, and tubular bags.
If you have a lead acid battery to charge it, it's important to keep it filled with water. If the battery runs out of water, it will no longer be able to generate power. The lead plates in the battery will start to corrode, and the battery will eventually fail. Will Tap Water Ruin a Battery?
Flooded electrolyte lead acid batteries do not cause thermal runaway because the electrolyte, which acts as a coolant in these batteries, helps prevent such an occurrence. Designers of flooded electrolyte lead acid batteries do not face the thermal runaway problems that are common in sealed maintenance free (SMF) or valve regulated lead acid (VRLA) batteries.
When considering basic materials, a customer needs to determine the type of battery chemistrythat will be used. All batteries will have components such as anodes, cathodes, and electrolytes, yet these components will be made of specific materials based on whether a customer selects a lithium-based battery, alkaline. Electronics and software are becoming standard components found in battery packs today. These components may consist of: 1. Protection. When deciding on the battery enclosure, it will be dependent on how the pack fits into application. For batteries that will be completely inserted into. Battery cell chemistries, configurations, materials, and components will have certain materials more available than others. The types of standard materials that are available will be. Battery cells can experience expansion and swelling due to thermal temperatures and a buildup of gases. This problem is common with lithium-based battery chemistries, as the cells can swell up to 10% during the lifetime of.
[PDF Version]Throughout the battery from a single cell to a complete pack there are many different materials. Aluminium, copper, nickel plating etc
Battery packs are constructed from two or more individual cells or batteries. There are two basic types of battery packs: primary and secondary or rechargeable. Primary batteries are disposable, non-rechargeable devices. They must be replaced once their energy supply is depleted.
Electronics and software are becoming standard components found in battery packs today. These components may consist of: Inside of custom battery pack showing electronics, components, and materials. Many of these components will be a part of the battery management system (BMS).
If the batteries will be mounted into the device, such as on the handle or in a separate housing that will need to be accessible, injection molded plastic is commonly used. In some circumstances, metal casings will be required for the battery pack. This option is suitable for battery packs that will be used for traction applications.
There are a lot of different kinds of packs. The battery pack is composed by single cell through series or parallel. Parallel increase capacity, voltage constant. Series increase voltage, capacity constant. For example, 72V 45Ah can be assembled by 3.6V 2500mah cylindrical battery cell in the mode of 18 parallel and 20 series.
All batteries will have components such as anodes, cathodes, and electrolytes, yet these components will be made of specific materials based on whether a customer selects a lithium-based battery, alkaline battery, or nickel-based battery.
These advanced materials include mica, intumescent materials, and ablative coatings. Each material offers unique properties and benefits suitable for different aspects of battery protection.
Foams also act as thermal and electrical conductors, depending on their material and the compression amount within the battery. An extra layer can be added to the foam to make it more suitable for EMI shielding. Battery components need protection from electromagnetic waves due to their high frequencies and small size.
Regarding EV battery production, foam ensures optimal performance and longevity. Foam is widely used as an insulation material within battery packs, protecting the cells from extreme temperatures and vibrations. This insulation not only enhances safety but also helps maximise energy efficiency.
One plug-in hybrid EV built in China is already using a thermoplastic polypropylene compound instead of aluminium for its battery case cover, providing savings in weight. Other EVs now in production around world are using several thermoplastic materials for components such as cell carriers and housings, battery modules and battery enclosures.
Polyurethane foam, silicone foam, and Ethylene-Vinyl Acetate (EVA) foam are commonly used foams in EV battery manufacturing. Each type serves specific purposes, such as thermal, electrical, and shock absorption. What are some advancements in foam technology for EV batteries?
Additionally, polyurethane foam provides structural support, reducing the risk of damage due to shocks or vibrations. Silicone foam, another popular choice, excels in maintaining electrical insulation. Creating a barrier against moisture and dust ingress ensures the battery pack's long-term reliability.
These foams are built with fire-resistant materials, ensuring if something such as thermal runaway occurs in the battery, the foam will be an essential factor in reducing the chances of spreading. Dielectric foams and insulation are critical components to protecting the battery cells as they expand and contract while in use.
An UPS battery is like a lifeline for your electronic devices, providing backup power during unexpected outages or fluctuations in the main power supply.
Uninterruptible Power Supply (UPS) Batteries. UltraMax UPS batteries for computers, telecom systems, plus many other devices Uninterruptible Power Supply (UPS) batteries are designed to ensure that power is maintained in the event of an outage.
L (mm) W (mm) H (mm) 151 98 97.5 Uninterruptible Power Supply (UPS) batteries are designed to ensure that power is maintained in the event of an outage. Without UPS batteries, losing power could be catastrophic, so it is important that you shop for the right batteries to meet the demands of your home or business.
Uninterruptible Power Supply (UPS) batteries are designed to ensure that power is maintained in the event of an outage. Without UPS batteries, losing power could be catastrophic, so it's important that you shop for the right batteries to meet the demands of your home or business.
Routine checks of the UPS and its battery are necessary to ensure that they are functioning correctly in case of an emergency. In conclusion, uninterruptible power supplies (UK) play a vital role in ensuring a continuous and uninterrupted supply of power to critical devices and systems.
Many smart devices have built-in battery packs, with modern laptops packing enough cells to last a whole day. However, typical desktop computers, routers, and similar devices still need to be plugged into a power source all the time to work. That's where an uninterruptible power supply (UPS) comes in.
Thus, UPS batteries are designed to discharge high currents for short periods. LiFePO4 (Lithium Iron Phosphate) batteries are a popular choice for use in Uninterruptible Power Supplies (UPS) due to their high energy density, long lifespan, superior safety and high discharge rate compared to other lithium-ion battery chemistries.
The battery control module is responsible for monitoring and controlling the state of charge of the battery, as well as regulating the current and voltage supplied to the battery. It also manages communication between various systems in the vehicle and the battery. The battery control module also plays an important role in. It depends on the battery control module (BCM). Some modules do not need to be programmed, while others require a specific programming sequence in order to function properly. Always consult the manufacturer's. A body control module can be repaired. However, the extent of the damage will determine if the module can be fixed or not. If there is extensive damage to the circuit board, then it may not be possible to fix it. If this is the case,. The battery control module can be tested. The best way to test it is with a scan tool that is operated by a qualified/professional technician. A scan tool will allow you to read and clear any. The location of the battery control module may vary depending on the type of vehicle. Some common locations are under the hood, in the trunk, or in the passenger compartment.
[PDF Version]In conclusion, the battery control module repair is a process that is necessary in order to maintain the function of the battery and ensure that it continues to operate at an optimal level. By bringing your vehicle in for this repair, you can be sure that your car will continue to run smoothly without any problems.
If your battery control module is not functioning properly, you may need to send it in for repair. Some common symptoms of a BCM that are not properly programmed include reduced run time, reduced capacity, and even full discharge of the battery pack.
In some cases, we may need to replace battery modules individually if they fail, rather than replacing the entire battery pack. It's important to note that it is important to get your battery serviced by an EV qualified technician, like our technicians here at Cedar Electric to ensure it is done safely and correctly.
Some tips to maintain battery control module are: -Clean the battery control module connectors with a wire brush. -Make sure the battery control module is properly grounded. -Check the fuses and relays in the engine compartment. -Monitor the state of charge of the battery. -Keep the battery terminals clean. -Check the charging system voltage.
High voltage batteries on electric and hybrid vehicles can be costly and sometimes they can actually be repaired. If the only option you have been given is to replace the battery it is worth checking with us if there are other options available. Here at Cedar Garage we offer services to test and overhaul your original battery.
Battery cell replacement involves replacing individual cells within the hybrid battery pack that have failed or degraded. This method allows for targeted repairs, reducing waste and expense. It can also extend the overall battery life. However, it may be challenging due to the need for specialized knowledge and tools.
The basic concept is that when connecting in parallel, you add the amp hour ratings of the batteries together, but the voltage remains the same. For example: 1. two 6 volt 4.5 Ah batteries wired in parallel are capable of providing 6 volt 9 amp hours (4.5 Ah + 4.5 Ah). 2. four 1.2 volt 2,000 mAh wired in parallel can provide 1.2. This is the big “no go area”. The battery with the higher voltage will attempt to charge the battery with the lower voltage to create a balance in the circuit. 1. primary (disposable). This is possible and won't cause any major issues, but it is important to note some potential issues: 1. Check your battery chemistries – Sealed Lead Acid batteries for example.
To properly wire a battery pack in series follow the illustration below. Some electric scooter, bike, and go kart batteries are wired in series and parallel to create a battery pack with a Voltage that is half the sum of all of the batteries in the pack combined.
A battery parallel assembly comprises multiple battery cells connected electrically in parallel under a specific topological configuration or geometrical arrangement. In this example, you create a parallel assembly of four cylindrical cells stacked in a square topology over four rows.
Flow batteries and other chemistries. These are commonly available in 48V. Multiple batteries can connect in parallel without any issues. Each battery has its own battery management system. Together they will generate a total state of charge value for the whole battery bank. A GX monitoring device is needed in the system.
When batteries are connected in series, the voltage increases. When batteries are connected in parallel, the capacity increases. When batteries are connected in series/parallel, both the voltage and the capacity increase. Single battery. Two batteries in series. Two batteries in parallel. Four batteries in series/parallel. Four batteries in series.
The basic concept is that when connecting in parallel, you add the amp hour ratings of the batteries together, but the voltage remains the same. For example: two 6 volt 4.5 Ah batteries wired in parallel are capable of providing 6 volt 9 amp hours (4.5 Ah + 4.5 Ah).
To wire multiple batteries in parallel, connect the negative terminal (-) of one battery to the negative terminal (-) of another, and do the same to the positive terminals (+). For example, you can connect four Renogy 12V 200Ah Core Series LiFePO4 Batteries in parallel. In this system, the system voltage and current are calculated as follows: